A thermal Finite Element Analysis (FEA) of the support column and its internal roof drain was generated. The result was a time-based determination of the temperature behavior of the concrete and brick column and PVC roof drain. This analysis confirmed that the temperature change inside the support column was sufficient to create an ice plug in the roof drain.